ANALISIS TINGKAT KERUSAKAN GEDUNG PADA KOMPLEK PERKANTORAN KANTOR BUPATI KUTAI KARTANEGARA
Keywords:
Capital Management, Business Efficiency, Geprek Mantul Karangjati, Cash Management, Inventory, Culinary SMEsAbstract
Building D is one of the buildings in the Office Complex of the Kutai Kartanegara Regent's Office. Over time the building will experience degradation. This will result in initial damage, so an inspection of the building condition is required. The results of the inspection with the visual inspection method of damage resulted in a damage value level of 20.32%, including the category of minor damage, while the test results with the Non Destructive Test (NDT) method are more structural in nature, where the test results with the Hammer Test resulted in a minimum compressive strength value of 17 Mpa in accordance with SNI standards regarding structural concrete requirements. For testing with UPV, it produces a wave velocity value of 3513 m/sec, which indicates the homogeneity of concrete is still quite good, while the results of the Rebar Scanner show that the dimensions of the reinforcement and the distance between the reinforcement are in accordance with the planning design and structural design standards
References
ASTM International. (2018). ASTM C805/C805M-18: Standard test method for rebound number of hardened concrete. ASTM International. https://doi.org/10.1520/C0805_C0805M-18
Baker, L., & Thompson, E. (2020). Rehabilitation Techniques for Damaged Buildings. Journal of Structural Engineering, 146(5), 77-86. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002498
Bidaj, A., Deneko, E., & Hysenlliu, M. (2019). Different reinforcement techniques in damaged buildings.
Kato, K., & Sato, M. (2020). Technological Advancements in Building Inspection. Journal of Building Engineering, 35, 101-112. https://doi.org/10.1016/j.jobe.2020.101112
Kurniawan, F. (2020). Analisis Kerusakan Akibat Pemakaian Beban Berlebih pada Gedung. Jurnal Manajemen Konstruksi, 25(2), 33-41.
Lee, K., & Park, H. (2017). Structural Failures in Office Buildings: A Case Study. Journal of Structural Safety, 73, 11-19. https://doi.org/10.1016/j.strusafe.2017.05.001
Natasya, & Wiyanto, H. (2022). Penilaian tingkat kondisi kerusakan elemen non-struktural gedung existing berdasarkan pemeriksaan visual.
Pratama, Y. (2023). Dampak Alih Fungsi pada Kerusakan Struktural Bangunan di Indonesia. Jurnal Konstruksi dan Arsitektur, 31(3), 29-37.
Pratama, R., & Nugroho, I. (2020). Design and Performance of Modern Office Buildings. Journal of Sustainable Architecture, 14(3), 101-113. https://doi.org/10.1108/JSA-03-2020-0023
Ramos, M., & Silva, T. (2021). Building Inspection Protocols for Government Offices. Journal of Facilities Management, 19(3), 45-58. https://doi.org/10.1108/JFM-09-2020-0079
Smith, J., & Brown, P. (2019). Building Failure Analysis: Causes and Solutions. Journal of Construction Engineering and Management, 145(3), 45-57. https://doi.org/10.1016/j.coneng.2019.03.004
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Andi Aqsar Hamzah , Eswan Eswan, Wahyu Mahendra Trias Admaja

This work is licensed under a Creative Commons Attribution 4.0 International License.