CONFUSION OF REAL SITE IMPLEMENTATION OF VSD UTILIZATION ON WATER PUMP OF A CHILLER PLANT SYSTEM IN OFFICE BUILDING JAKARTA
DOI:
https://doi.org/10.33758/mbi.v18i8.740Keywords:
Variable speed drive (VSD), temperature, chiller efficiency, HVAC System Energy consumptionAbstract
The utilization of VSD in centralized air conditioning systems has been applied for years for efficiency purposes. However, found in real implementation has not been really applied as its function yet. This paper will present real site implementation of applying VSD on regulating the motor speed of chilled water pump as its function [1] to control the chilled water flow rate [2] go into the evaporator to let the chiller work as correspond on cooling demand at the actual load level and at its necessary power input. By analyzing some related parameters such as temperature, water pressure and amperes measured and observed to be the raw data then they will show the working performance of chiller impact on energy consumed to be evaluated on its efficiency impact. Found the real implementation at this site the VSD does not look like varying the speed of motor pump as usually applied but more by being set at certain frequency such as 32 Hz. Then mostly the chiller cannot be run as high as cooling demand as running at only about 50-60% as lower chilled water flow rate flowing into the evaporator. Other than that it looks efficiency of refrigeration effect on handling the building load is not good enough as mentioned in catalogue/reference with difficulties on reaching the target chilled water leaving temperature.
References
I. Kusuma, "Aplikasi VSD Dalam Penghematan Konversi Energi," Sainstech, p. 1, 2016.
D. Watanabe, "The Influence of Optimizing The Difference of Water Flow Rate to Energy Efficiency," Research India Publications, p. 1, 2017.
M. S. Y. T. A.-Q. Y. N. Jaehun Lim, "Feasibility Study on Variable-Speed Air Conditioner under Hot Climate based on Real-Scale Experiment," MDPI, p. 2, 2019.
M. Luigi Schibuola, "Variable Speed Drive Technology Applied to HVAC System for Energy Savings," Elsevier Energy Procedia, p. 1, 2018.
M. F. H. Z. M. S. Hazlina Selamat, "Review on HVAC System Optimization Towards Energy Saving Building Operation," International Energy Journal, p. 1, 2020.
S. N. Patrialova, "The Characteristic of Variable Frequency Drive fot Water Flow Control," The Journal of Engineering, p. 1, 2021.
R. M. E.-M. M. F. Mohamed Sadek, "Evaluation of Variable Speed Drives to Improve Energy Efficiency and Reduce Gas Emissions," CI & CEO, p. 3, 2023.
L. L. E. H. M. Gideon Edgar Du Plessis, "The use of variable speed drives for cost-effective energy savings in South African Mine Cooling System," Elsevier, p. 2, 2013.
Johnson Controls, Air Cooled Condenser Chiller, Johnson Controls Inc.
"Air Cooled Screw Chiller Performance Datasheet," Johnson Control Inc, Milwaukee, 2022.
N. S. E. G. K. Karunakaran, "Variable Speed Compressor based Energy Savings in Air Conditiong System," ResearchGate, p. 3, 2019.
R. M. M. Mohamed Sadek, "Evaluation of Variable Speed Drive to Improve Energy Efficiency in Case Study," p. 5, 2023.
Downloads
Published
Issue
Section
License
Copyright (c) 2024 Marhaendra Natawibawa
This work is licensed under a Creative Commons Attribution 4.0 International License.